Route the belt slack around the idler pulley and motor pulley — consult your dryer's service manual or a model-specific video for the correct belt path around the pulleys
Opens at 352°F — one-time backup safety device on the heating element housing · Permanently interrupts power to the heating element if the high-limit thermostat fails to protect it · Cannot be reset — must be replaced if blown · Should show closed continuity at room temperature when working
TEDX540RQ1
G000187484
Opens at 295°F — cuts power to the heating element if temperature exceeds safe levels · Auto-resets when cooled · Located on the heating element housing · Should show closed continuity (near-zero resistance) at room temperature
ERP 241854401 Refrigerator Evaporator Fan Motor Hose Route the belt slack aroundERP 241854401 Refrigerator Evaporator Fan Motor 120V, 60Hz, 6W, . 1A, 1 3 4" shaft, Has quick disconnect. Replaces Part Numbers: 241854401, 1483567, AH2350613, AP4374248, EA2350613, PS2350613. This is an aftermarket part that can be used as a replacement for the OEM part. California Residents only WARNING: Cancer and or Reproductive Harm www. p65warnings. ca. gov